| We are well-reckoned as one of the major Industrial Fire Detectors Suppliers in India. An automatic fire detection & alarm system consists of Fire Detector & Manual Call Points positioned in zones/loop throughout a building. These are wired to control & indicating equipment which shows the location of the alarm clock, & actuates audible alarm sounders. We also provide Wholesale Automatic Fire Alarm System at the most profitable deals. Normally the following systems are installed in the premises:
- Addressable, Intelligent, Analogue Fire Detection & Alarm System. Automatic Micro Processor based Fire Detection & Alarm System.
- Integrated Fire Detection, Alarm & Extinguishing System.
- Conventional Fire Alarm & Detection System.

Application
- Industrial/ Non Industrial Buildings.
- Institutional Buildings.
- Residential Apartments.
- Hotel & Hospitals.
- All Industries.
- Malls & Multi Storied Complexes.
- Offices & Control Rooms.
Basic Features :
- Easy Installation
- Easy Operation
- Easy to Maintain
Standard Features :
- Complies to IS 2189 : 1999 and Tested by ERTL (N).
- 2 X 16 character backlit LCD display
- Lamp test feature
- Complete with intergral power supply and battery charger for sealed lead acid battery.
- NO/NC contacts for both fire and fault
- Switches to enable on board operation
- LCD and LED indication for open, short circuit, isolate, fire in each zone.
- Maximum nos. of Detectors in each zone is 25
Optional Features :
- 4 X 20 character backlit LCD Display.
- 2 wire communication facility via RS 485 Port
- BMS attatchment. / Repeater panel facility. (2 wire with LCD)
- 256 / 512 Events logging facility with real time clock and keypad.
- Computer attatchment with printer facility
- Output fpr extiguising facility and activated when alarm from 2 cross zones. (Time Delay 0-99 Sec.)
|
Specification
| Electrical Specification | | | Operating Voltage | 24 Volts DC | | Stand By Batteries | 24 Vilt DC (2 X 12 Volt DC) | | Power Supply | | | Mains | 220 VoltAC, 50 Hz to the internal mains transformer (+10%) | | Inputs | 26 Volt From Internal Mains Transformer | | Output | 24 Volt DC : 12 volt DC . (Regulated) | | Charging Voltage | 27.2 Volts DC. | | End of Line Resistor | 4.7 K Ohm, One per zone | | Enviromental Operating Limits | | | Temprature | 0 deg. C to 50 deg. C | | Humidity | 90% to 95% RH condensing | | Dimension (MM) | 275 x 325 x 95 (2 Zone & 4 Zone) | | Weight | 3.920 Kg. | | Construction | | | Material | 1.6 / 1.8 mm CRCA sheet duly powder coated | | Cable Entry | From top and back (20 mm knock outs) | | no. of zones | 2 to 60 zones | | External Output | | | Sounder Outpit | Comon hooter with number of individual output per zone. | | Aux. Relay Output | One each for fire and fault can be expanded according to the individual requirement | | Approvals | | | Department | BSNL, PWD, CPWD, Banks and other Private and Govet. Department. | | Tested By | ERTL (N) | | Zone Display | | | Green LED | Zone Healthy | | Amber LED | Isolate, short & open | | Dual Red LED | Fire | | LCD Display | 2 x 16 character indicating complete status of zone | | |
Internal Sounders : Continuous buzzer for the fault condition intermittent buzzer for the fire condition.
User Controls : Reset, Lamp Test, Silence, Isolate, Short, Open, Fire.
LED Indication on Panel : Main ON, Charging On, System On, Battery Low, Stand By On, Earth Buzzer Silence, Alarm Silence Zone On, Zone Isolate, Short, Open, Alarm.
LCD Indication on Panel : Zone Status
|
| | |
|
|
|